Категория | PA66, Polyamide 66 Alloy , Nylon 66 Alloy |
Производитель | Polymer Dynamix |
Торговая марка | DynaMix™ |
Порт | Китай Шанхайский порт |
Торговые условия | FOB, CFR, CIF |
Платежное средство | L/C, T/T, Western Union |
hgKkHZ_DynaMix-XP-66LGR.pdf | |
Контактная информация | Служба поддержки клиентов Вичат |
|
Главная Информация | |
---|---|
Наполнитель/армирование |
|
Характеристики |
|
Используется |
|
Физический | Номинальное значение | Единица измерения | Метод испытания |
---|---|---|---|
Удельный вес | 1.75 | g/cm³ | ASTM D792 |
Механические | Номинальное значение | Единица измерения | Метод испытания |
---|---|---|---|
Модуль растяжения | ASTM D638 | ||
-- 1 | 18600 | MPa | |
-- | 23800 | MPa | |
Прочность на растяжение | ASTM D638 | ||
Break 2 | 193 | MPa | |
Break | 293 | MPa | |
Удлинение при растяжении | ASTM D638 | ||
Break 3 | 3.4 | % | |
Break | 2.3 | % | |
Флекторный модуль | ASTM D790 | ||
-- 4 | 15500 | MPa | |
-- | 20700 | MPa | |
Flexural Strength 5 | 310 | MPa | ASTM D790 |
Воздействие | Номинальное значение | Единица измерения | Метод испытания |
---|---|---|---|
Зубчатый изод Impact | ASTM D256 | ||
-- 6 | 1500 | J/m | |
-- | 130 | J/m | |
Незубчатый изод Impact | ASTM D256 | ||
-- 7 | 120 | J/m | |
-- | 1200 | J/m |
Тепловой | Номинальное значение | Единица измерения | Метод испытания |
---|---|---|---|
Температура отклонения при нагрузке (1.8 MPa, Unannealed) | > 250 | °C | ASTM D648 |
Температура плавления | 260 | °C |
Примечание | |
---|---|
1 . | 50% Rh specimen accelerated conditioning was conducted in accordance to modified ISO-1110 procedure Specimens were conditioned in sealed chamber at 70°C and 50% Rh for at least 2 weeks. |
2 . | 50% Rh specimen accelerated conditioning was conducted in accordance to modified ISO-1110 procedure Specimens were conditioned in sealed chamber at 70°C and 50% Rh for at least 2 weeks. |
3 . | 50% Rh specimen accelerated conditioning was conducted in accordance to modified ISO-1110 procedure Specimens were conditioned in sealed chamber at 70°C and 50% Rh for at least 2 weeks. |
4 . | 50% Rh specimen accelerated conditioning was conducted in accordance to modified ISO-1110 procedure Specimens were conditioned in sealed chamber at 70°C and 50% Rh for at least 2 weeks. |
5 . | 50% Rh specimen accelerated conditioning was conducted in accordance to modified ISO-1110 procedure Specimens were conditioned in sealed chamber at 70°C and 50% Rh for at least 2 weeks. |
6 . | 50% Rh specimen accelerated conditioning was conducted in accordance to modified ISO-1110 procedure Specimens were conditioned in sealed chamber at 70°C and 50% Rh for at least 2 weeks. |
7 . | 50% Rh specimen accelerated conditioning was conducted in accordance to modified ISO-1110 procedure Specimens were conditioned in sealed chamber at 70°C and 50% Rh for at least 2 weeks. |
Тип материала | Категория | Производитель |
---|---|---|
RTP 204H FR | Nylon 66 | RTP Company |
Next Nylon 66 Prime Series PGHSLR30-01BK | Nylon 66 | Next Polymers Ltd. |
Hylon® N1015MDHL | Nylon 66 | Ravago Manufacturing Americas, LLC |
TORZEN® G3300L NC01 | Nylon 66 | INVISTA Engineering Polymers |
Vydyne® R513H Black | Nylon 66 | Ascend Performance Materials Operations LLC |
AKROMID® A3 GK 30 1 natural (3673) | Nylon 66 | AKRO-PLASTIC GmbH |
Телефон | +086 13424755533 |
EMAIL US | sales@su-jiao.com |
Служба поддержки клиентов Вичат |